D-2000 Software Release Note

****** Version 4.0.0 ******

(ADDITIONAL FUNCTION)

1.Added the Change Safe function

2.Added the Channel Mute and All Mute function

3.Added the Fader layer recall function assigned to the preset memory

4.Changed the initial value of serial port control speed
  *Changed from 115200bps to 9600bps

5.Added the external control protocol
  *Fader layer recall
  *Fader group setting
  *Fader fine gain command
  *Channel mute
  *External control switch
  *Gate Status

6.Changed the max value of CobraNet conductor priority
  *Changed From 255 to 128(Recommended max value)

[PC Software] 

1.Added Routing Monitor View

2.Two or more crosspoints can be selected in Matrix View

3.Added User Level and Restriction Settings

4.Added Box Protection function 
  (Restricting each box's parameter change)

5.Added Polarity reverse button on Xover box

6.Added VCA operation indicator on Fader View VCA tab

7.Added Console Setting Window
  *This setting can be made to up to 4 fader layers each of up to 4 D-2012C units.

8.Added Console SEL/MONI key link function
  *interlock with Box selection

9.Added Box selection by arrow key operation while pressing the Ctrl key on the keyboard

10.Changed button color
  *FBS DYNAMIC mode ON/OFF button
  *Filter Box On/Off button
  *Xover Box Polarity button

11.Changed CD bundling contents
  *Added Setting data samples and the commentary document
  
  *Bundled external control protocol document data

12.Supported the latest OS
  *Windows Vista 64bit and Windows 7 32/64bit


(MODIFICATION)

The following errors were corrected:

1.Fixed a bug where the additional xover filter may not work when the unit configuration change.

[D-2008SP]
1.Fixed a bug where D-2008SP freezes when the Filter of frequency 12kHz is set.

2.Fixed a bug where audio signals may not be output when grouping numbers of the fader which set VCA are different by preset memory.

3.Fixed a bug where the VCA level does not link.

4.Fixed a bug where it is not reconnected normally when a PC is in the sleep state.

5.Fixed a bug where the compressor does not work normally when the attack time was set at the long time of 3-4 seconds.

[D-2012C] 
1.Fixed a bug where a fader level may be edited when FaderLayer is changed in succession.

2.Fixed a bug, when PC that placed on the same LAN restart, D-2012C may freeze.

[PC Software] 
1.Fixed a bug where delay value may not be reflected when numerical value inputs.

2.Fixed a bug where the filter of the stereo channel cannot be set to the remainder maximum number.

3.Fixed a bug where the Line Input function in Slot8 position at console function key setting does not work.

4.Fixed a bug where the FBS auto mode does no work. (Ver.4.0.1)

***************************

****** Version 3.0.0 ******

(ADDITIONAL FUNCTION)

1.For D-2000 full system
 *The largest-scale system can be configured with 4 D-2008SPs, 4 D-2012Cs(except for CU), and 1 PC.
 *Audio Monitor Line Connection can be configured when multiple units are connected.

2.Added CobraNet Setting parameters
 *Setting parameters (Latency, Bit length, Conductor priority)
 *CobraNet Bundle Matrix dialogue

3.Added CobraNet PRIMARY and SECONDARY Link indication[PC Software]
 *On Unit view, FAN Status indication is modified when failure occurs only.

4.Added Boxes Copy, Paste and Initialize functions on Flow view
 *FBS Box is enabled only when in online mode.

5.Changed Boxes operation on Flow view
 *Controls on the Box can be operated after the Box selected.
 *The same kind boxes are enabled to operate straightly.

6.The "On" color is changed that displayed in tabular form at filter view .

7.Added Split mode on LevelMonitorView
 *Two positions of LevelArea can be displayed at one processor unit.

8.A console fader layer which assigned no channel can be recalled.

9.Added TCP/IP port control

10.Added connection status view

11.Added contact status view

12.Changed the reflesh positions of floating Contents view and Levelmonitor view.

13.Changed Word clock synchronization setting
 *Prohibit a setting change when in online mode.
 *When CobraNet setting used, CobraNet sync can be only selected.
  (External sync can not be selectable)

14.Improved the feel of speed
 *Reduction of the memory consumption
 *Data transfer speed at connection, and refleshing the screen of PC.

15.Added file import function

16.Improved the selected operation at Comp/Leveler mode selection button.

17.Saved the delay increments units and matrix channel name display state

(MODIFICATION)

The following errors were corrected:

[PC Software]

1.Fixed a bug where the abnormality file-size when saving file.

2.Fixed a bug where the application crash when the box drag & drop on Flow view.

3.Fixed a bug where the focus can not move from the floating window to main window.

4.Fixed a bug where the application crash when the stereo link setting is changed when selected an even number channel on Flow view

5.Fixed a bug where the reduction level meter at compressor

*************************